Richentek Industry Co., Ltd — Feed & Aquatic Feed Machinery Since 2006info@pelletmachines.netWhatsApp: +86 186 0385 1787YouTube @PelletMachines
COUNTERFLOW COOLING · NL-11 / NL-14 · AMBIENT +3–5 °C

Counterflow Pellet Cooler Cooling Pellets to Storage Temperature Before Bagging

Pellets leave the pellet mill at 70–90 °C and soft. Bagged at that temperature they sweat, cake and grow mould within days. A counterflow cooler moves ambient air upward through a downward-moving pellet bed, bringing temperature to within 3–5 °C of ambient and removing the moisture that causes the problem.

Reference FOB price: USD 3,200 – 9,800 by model. Fan, cyclone and airlock sized with the cooler, not after it.

Counterflow pellet cooler for feed pellet plants
1–5T/H per unit
≥6–10min cooling time
+3–5°C above ambient
2 yrWarranty + lifetime parts
What it is

The Machine That Decides Whether Your Feed Survives Storage

Cooling is underrated until it fails. Hot pellets in a bag generate moisture, moisture grows mould, and the whole batch is lost. Cooling also hardens the pellet surface, which is what keeps it whole through conveying, screening and transport.

A bed, not a box of hot pellets

Pellets drop onto the top of a static bed and travel down it under their own weight. The bed is the heat exchanger: every pellet spends six to ten minutes in contact with air that is always colder than it is.

The chamber is divided into three zones. The hottest pellets meet already-warmed air at the top (S-3), the middle zone does most of the moisture transfer (S-2), and the coolest pellets meet fresh ambient air at the bottom (S-1). Nothing is cooled faster than it can take.

The airlock under the discharge sets how fast the bed falls, and that one speed is what controls retention time. Slow the airlock and the bed deepens; speed it up and the bed thins.

Cutaway of a counterflow pellet cooler showing the pellet bed and the three cooling zones
Cutaway — the bed rests on the perforated discharge deck. Air comes in under S-1 and leaves above S-3.
Counterflow principle

Cool air, hot pellets

Air enters at the bottom and rises; pellets move down. The coldest air meets the coolest pellets — no thermal shock, no cracking.

Temperature target

Ambient +3–5 °C

The accepted industry target for safe bagging and storage.

Moisture removal

2–3 percentage points

Cooling air removes the moisture added during conditioning.

Surface hardening

Fewer fines

Cooled pellets resist breakage in screening, conveying and transport.

Counterflow pellet cooler with cyclone dust collector and discharge screw conveyor
The complete air system: chamber, cyclone, airlock and discharge screw. The cyclone is where fines leave the air before it reaches the fan.
Counterflow pellet cooler on a blue steel frame with inspection window
The same chamber on a bolted frame. The inspection window lets an operator read bed depth without opening the door.
Models & technical data

Counterflow Pellet Cooler Specifications

Match the model to your pellet mill output — and remember that a cooler sized to the mill at full load is the minimum, not the maximum.

Counterflow cooler — NL series

Model Capacity (t/h) Power (kW) Overall size L × W × H (mm) Weight (kg)
NL-11 1–2 1.55 + 5.5 2050 × 1320 × 3200 500
NL-14 2–5 1.55 + 7.5 2480 × 1700 × 3400 1,100

Cooler and sifter in one body — LQ-50 / LQ-70

Model Capacity Power (kW) Overall size L × W × H (mm) Weight (kg, body + assembly)
LQ-50 0–500 kg/h 0.75 + 2.2 1800 × 750 × 1100 220 + 65
LQ-70 0–1,000 kg/h 0.75 + 2.2 + 2.2 1800 × 750 × 1100 220 + 120

Figures are the values on our factory sheet. Power is the motor set: for the NL series the airlock and fan motors, for the LQ series the fan and the sieve-drive motors. Weight is quoted as the main body plus the separate assembly that ships with it. Cooling time ≥ 6–10 minutes; pellet temperature after cooling ≤ ambient +3–5 °C.

Why cooling time cannot be rushed

Six to ten minutes is the practical retention needed to cool a pellet through its full section, not just its surface. Shortening retention cools the outside while the core stays hot — and the core is what generates moisture in the bag.

If your line runs faster than the cooler can hold, output quality drops even though throughput looks fine.

The undersizing trap

The most common mistake in a feed plant is a cooler one size too small for the pellet mill. It works in winter, struggles in summer, and fails completely in a hot humid climate — which is exactly where most of our customers operate.

Tell us your ambient summer temperature when you enquire and we size accordingly.

Quick quote — cooler and air system

Tell us your pellet mill model, target T/H and maximum ambient temperature. We reply with the cooler model, fan and cyclone sizing. Send the details to info@pelletmachines.net or WhatsApp +86 186 0385 1787 — engineers reply within 12 hours.

    ≥6–10min cooling time
    +3–5°C above ambient
    1.55kW airlock drive
    2–3points moisture removed
    Working principle

    Why Counterflow Beats Crossflow

    Air direction is the whole design. Getting it backwards cracks pellets and cools unevenly.

    1

    Pellets enter

    Hot pellets at 70–90 °C enter the top of the cooler and form a bed.

    2

    Air rises

    Ambient air is drawn in at the bottom and pulled upward through the bed by the fan.

    3

    Counterflow exchange

    The coldest air meets the coolest pellets at the bottom — gradual cooling that avoids thermal shock and cracking.

    4

    Moisture removal

    Warm air carries away the moisture added during steam conditioning.

    5

    Discharge

    An airlock discharges cooled pellets at ambient +3–5 °C to the crumbler or sieve.

    Airflow diagram of a counterflow pellet cooler
    The air path in one picture: ambient air in at the bottom, hot moist air out at the top, pellets down through S-3 to S-1 and out through the airlock.
    Front and side elevation drawings of a counterflow pellet cooler
    Front and side elevations. Overall height is the number that decides whether the cooler fits under your roof — 3,200 mm for NL-11, 3,400 mm for NL-14.
    Feed Pellet Cooler Structure and Working Principle Video Show

    Feed pellet cooler — structure and working principle

    Inside the cooling chamber: bed formation, air path, airlock discharge and the fan system.

    Feed Pellet Machines Showroom: Complete Animal Feed Pellet Plant Solutions

    Showroom — coolers inside complete feed plants

    See the cooler positioned between the pellet mill and the crumbler and sieve.

    Sizing guide

    Which Cooler for Which Pellet Mill

    Match cooler capacity to mill output with margin for your hottest month.

    Pellet mill Mill output (t/h) Cooler Why this one
    PM-200 flat die 0.2–0.4 LQ-50 Cools and sieves in one body — no separate sieve to buy
    PM-260 / PM-300 / PM-330 0.4–0.9 LQ-70 The 1 t/h unit; the standard fit on 600–800 kg/h lines
    HM-250 / HM-320 ring die 0.8–3 NL-11 Separate chamber, pair it with a grading sieve
    HM-350 / HM-400 ring die 3–5 NL-14 2–5 t/h; 3,400 mm tall, so check headroom
    HM-420 / HM-508 ring die 5–8 2 × NL-14 Two units in parallel — also the fit for a 6,000 kg/h line

    Aquatic and shrimp feed need longer cooling than poultry feed. If you make both, size the cooler for the aquatic product — the same rule applies to the LQ series.

    Second family

    When Cooling and Sieving Should Be One Machine

    Below about 1 t/h a separate cooler and a separate sieve cost more floor space and more ducting than they are worth. The LQ series puts both jobs in one horizontal body: pellets are cooled on a perforated deck while that same deck shakes the fines out of them.

    One deck, two jobs

    Pellets enter at the top, slide across a perforated deck while ambient air is pulled through from below, and leave at the discharge end already screened. Fines drop through the perforations and are collected separately, so nothing carries over into the bag.

    Because the deck is short, retention is short too — that is why the LQ tops out at 1 t/h. Above that the counterflow chamber gives the pellet the six to ten minutes it needs.

    The whole unit is 1,800 mm long and 1,100 mm high, so it ships in one piece and sits on a flat floor. No pit, no steel structure, no second machine.

    Compact cooler and sifter unit with horizontal cooling chamber and sieve deck
    LQ unit on its frame. The gear motor on the side drives the sieve deck; the fan underneath pulls air up through it.
    Cooling and sieving

    Two jobs, one pass

    Pellets are cooled and screened in the same pass, so there is no second machine to buy, power or maintain.

    Noise and dust

    Quiet, low dust

    A low-speed deck and a sealed body keep noise and dust inside the machine. No separate aspiration hood is needed.

    Service life

    Simple to keep running

    Few wearing parts: one fan, one or two sieve drives and the deck itself. Screen changes take minutes and need no special tools.

    Footprint

    Small enough to ship whole

    1.8 m long and 1.1 m high, and it breaks into two assemblies for transport — it fits a container without dismantling.

    From our workshop

    Coolers in Build, in Test and in the Line

    Every unit is assembled and run before it ships. These are coolers at different stages — on the frame, under the conveyor, and working in a customer plant.

    Operating notes that prevent most problems

    Bed depth must be controlled. Too shallow and air short-circuits; too deep and the fan cannot pull through. The discharge airlock sets the bed depth, and its speed is the control you use.

    Airflow must be enough. An undersized fan is the second most common cooler problem after undersizing the cooler itself. We supply the fan and cyclone matched to the model.

    Clean the air chamber regularly. Fines accumulate in the plenum and screens, quietly cutting airflow week by week until cooling performance falls off without an obvious cause.

    Discharge end of a counterflow pellet cooler above the grading sieve
    • Counterflow design — no thermal shock, no cracked pellets
    • Cooling to within 3–5 °C of ambient temperature
    • Removes 2–3 percentage points of moisture added in conditioning
    • Hardens pellet surface, reducing fines in handling
    • Airlock discharge controls bed depth and retention time
    • Fan and cyclone supplied matched to the cooler model
    FAQ

    Counterflow Pellet Cooler Questions

    How much does a counterflow pellet cooler cost?
    Reference FOB ranges from about USD 3,200 for the LQ-50 up to USD 9,800 for the NL-14, depending on whether the fan, cyclone and airlock are included.
    Which model do I need?
    Match it to your pellet mill output with margin for your hottest month. The sizing table above gives the pairing; tell us your maximum ambient temperature and whether the product is aquatic or poultry and we confirm.
    Why can I not just cool pellets naturally?
    You can at very small scale by spreading pellets on a floor, but it is slow, needs space and labour, and cools unevenly. From about 1 t/h upward a mechanical cooler is cheaper per ton and far more consistent.
    How long does cooling take?
    Six to ten minutes of retention in the cooling chamber. That is the time needed to cool a pellet through its full cross-section rather than just its surface.
    What temperature do pellets reach?
    Within 3–5 °C of ambient temperature, which is the industry target for safe bagging and storage.
    Does it remove moisture as well as heat?
    Yes — typically 2–3 percentage points, which removes the moisture added during steam conditioning. That is why cooled pellets store without moulding.
    Does aquatic feed need a bigger cooler?
    Usually yes. Aquatic and shrimp feed retain more moisture and need longer cooling than poultry feed. Size the cooler for the most demanding product you make.
    What is the warranty and spare parts situation?
    Two-year warranty, lifetime spare parts supply, installation guidance and optional commissioning. Airlocks, screens and fan parts are stocked for fast dispatch.

    Ask for a cooler sizing recommendation

    Send your pellet mill model, target T/H, product type and maximum ambient temperature. You get the cooler model, air system sizing and investment range within 12 hours. Send the details to info@pelletmachines.net or WhatsApp +86 186 0385 1787 — engineers reply within 12 hours.

      Get Your Cooler Sized for Your Climate

      Send your pellet mill model, tonnage, product type and maximum ambient temperature. You get the cooler model, matched air system and investment range within 12 hours.