Richentek Industry Co., Ltd — Feed & Aquatic Feed Machinery Since 2006info@pelletmachines.netWhatsApp: +86 186 0385 1787YouTube @PelletMachines
COOLING + SIEVING IN ONE BODY · LQ-50 / LQ-70 · 0–1,000 KG/H

Cooler and Sifter Machine Cool, Screen and Discharge Pellets in One Pass

Cooling and screening are usually two machines, two motors and a run of ducting between them. The LQ series does both inside one horizontal body: pellets leave the die at 70–90 °C, travel across a perforated deck that air is pulled through, and arrive at the discharge cool, whole and free of fines — in one pass.

Reference FOB price: from USD 3,200 for the LQ-50, fan and filter unit included. The model is set by your pellet mill output, not by the bag.

Cooler and sifter machine, LQ series, with horizontal cooling and screening chamber on a blue frame
0–1,000kg/h throughput
2models: LQ-50, LQ-70
5.15kW total on the LQ-70
1.8 × 0.75m footprint, both models
What it is

One Body, Two Jobs — Cooling and Screening

Buy a cooler and you still need a sieve, its motor, its fines return and the ducting between the two. Below about 1 t/h that is more floor space and more maintenance than the work justifies. The LQ series puts both jobs on one frame — and, more importantly, on one deck.

The deck that cools is the deck that screens

Hot, moist pellets enter at the top of the horizontal chamber and slide across a perforated deck. Ambient air is pulled down through the bed by the fan while the deck runs, so each pellet is cooled from underneath and screened at the same time.

Crumbs and dust fall through the perforations to a separate fines outlet; whole pellets ride over the deck to the discharge. Nothing carries over into the bag, and the fines can go back to the mixer instead of being sold as dust.

A short deck means short retention — three to five minutes. That is exactly why the LQ stops at 1 t/h, and why larger lines use the counterflow chamber instead.

Cooler and sifter unit with its centrifugal fan and filter-bag dust collector in a feed mill workshop
The complete unit: cooling and screening chamber on the left, fan and filter-bag dust collector on the right. The bags are where the air leaves, so the dust stays out of the room.
Cooling

Cool and even

Air is drawn through the whole bed rather than across its surface, so pellets leave at one temperature instead of hot on one side and cold on the other.

Screening

Fines out before the bag

The perforated deck takes out crumbs and dust in the same pass, and the moving pellet layer keeps the openings clear, so screening efficiency stays high through a shift.

Running

Low noise, low dust

The fan sits on a resilient mount and the chamber is closed. The unit runs quietly and puts very little dust into the packing area.

Service

Simple to keep

No gearbox and no chains — one deck drive and one or two fan motors. Screens lift out for cleaning, bearings are greased from outside, and the body moves with a pallet truck.

Cooler and sifter with cyclone dust collector and flexible ducting in a feed mill
Cyclone version for plants that already run a central dust system — the fines land in the cyclone instead of the filter bags.
Two cooler and sifter units installed side by side in a feed mill workshop
Two units on a workshop floor. Each has its own fan, so one can be serviced while the other keeps the line running.
3–5min on the deck
0.75kW deck drive
2.2kW per fan
220kg body weight
Working principle

What Happens Between the Die and the Bag

Five stages, one frame. The only setting an operator touches is the discharge gate, which sets how deep the pellet bed sits on the deck.

1

Pellets in

Hot pellets at 70–90 °C drop from the pellet mill discharge into the inlet end of the chamber.

2

Air through the bed

The fan pulls ambient air down through the perforated deck and up through the pellet layer — the bed itself is the heat exchanger.

3

Fines drop through

Crumbs and dust fall through the deck perforations to a separate fines outlet under the chamber.

4

Cooled pellets out

Whole, cooled pellets ride over the deck to the discharge spout, within a few degrees of ambient and ready to weigh.

5

Air cleaned

Dust-laden air passes the filter bags or cyclone before the fan, so the workshop stays clean and the fan stays balanced.

Discharge end of a cooler and sifter with four outlets beside a feed pellet mill
The discharge end: cooled pellets leave through the spouts while fines drop out separately underneath. The pellet mill is right behind it.
Blue cooler and sifter unit on a pallet in the assembly workshop with its filter unit
A unit on the assembly floor before dispatch — chamber, deck drive, fan and filter unit are assembled and run together here.
Models & technical data

Cooler and Sifter Specifications — LQ-50 and LQ-70

Both models share one body and one 1,800 × 750 × 1,100 mm footprint. The difference is the fan: the LQ-70 carries a second 2.2 kW fan and doubles the throughput.

Cooler and sifter — LQ series

Model Capacity Power (kW) Overall size L × W × H (mm) Weight (kg, body + assembly)
LQ-50 0–500 kg/h 0.75 + 2.2 1800 × 750 × 1100 220 + 65
LQ-70 0–1,000 kg/h 0.75 + 2.2 + 2.2 1800 × 750 × 1100 220 + 120

Power is listed motor by motor: 0.75 kW deck drive, then one 2.2 kW fan on the LQ-50 and two on the LQ-70. Figures are the values on our factory sheet. Tell us your pellet diameter, product and climate and we confirm the fan selection for your site.

Which model for which pellet mill

Pellet mill Mill output (t/h) Cooler and sifter Why this one
PM-200 flat die 0.2–0.4 LQ-50 Smallest flat die — one fan is enough
PM-260 / PM-300 / PM-330 0.4–0.9 LQ-70 The standard fit on 400–800 kg/h lines
PM-400 flat die 0.8–1.2 LQ-70 Top of the LQ range — check pellet diameter and your hottest month
HM-250 / HM-320 ring die 0.8–3 NL-11 counterflow Above 1 t/h use the counterflow cooler with a separate sieve

A cooler sized to the mill at full load is the minimum, not the maximum. If your ambient air reaches 35 °C in summer, take the next model up rather than running the fan flat out.

Where it fits

The Last Machine Before the Bag on a Small Line

On a 200–800 kg/h feed line the LQ sits between the pellet mill and the bagging scale. Nothing else is needed in between.

No tower, no elevator, no separate sieve

Pellets come off the die hot and are cool enough to bag three to five minutes later. On a flat-die line with no bucket elevator the unit is usually fed by a short inclined belt from the mill discharge and drops straight into the bagging hopper.

That is the practical advantage of a horizontal body: it needs about two metres of headroom, not the six to eight metres a counterflow cooler tower needs.

If the line runs two shifts, two LQ-70s on a common frame usually cost less than one larger cooler plus a separate sieve — and either unit can be serviced while the other keeps running.

Small flat die feed pellet line with cooler and sifter at the discharge end
A small flat-die line: the cooler and sifter sits at the discharge end, feeding straight into the bagging scale.
Two cooler and sifter units with cyclones ready for dispatch
Two units built as a pair for a plant that runs two shifts — either one can be opened for cleaning while the other stays on line.
White-bodied cooler and sifter beside a feed hammer mill on a pellet line
White body option, here beside a hammer mill. Body colour is your choice; the deck, fan and frame are the same.
Operating notes

Four Things That Decide How Well It Runs

None of these needs a technician. All four are worth five minutes a week.

Bed depth

Keep the deck covered

The discharge gate sets bed depth. A shallow bed cools quickly but screens badly; keep pellets covering the deck along its full length.

Screen

A torn screen puts crumbs in the bag

Check the deck weekly and keep one spare. A split screen is the usual cause of sudden fines in a bag that was clean last month.

Filter bags

Dust on the floor is a signal

Dust settling around the unit usually means a bag is split or the fan is pulling harder than the bags can pass.

Fines

Send them back, do not bin them

Fines off the LQ are good material. Return them to the mixer and they become pellets again.

FAQ

Cooler and Sifter Questions

What is a cooler and sifter machine?
One machine that cools pellets and screens fines out of them in the same pass. Hot pellets travel across a perforated deck while a fan pulls ambient air through the bed; crumbs fall through the deck to a separate outlet and whole pellets leave at the discharge.
What capacity does it handle?
The LQ-50 runs 0–500 kg/h and the LQ-70 runs 0–1,000 kg/h. Both share the same body and the same 1,800 × 750 × 1,100 mm footprint.
How much does a cooler and sifter cost?
Reference FOB starts at about USD 3,200 for the LQ-50 with its fan and filter unit. The LQ-70 is quoted with the second fan, ducting and your discharge arrangement.
Can it replace a separate cooler and sieve?
Below about 1 t/h, yes — that is what it is for. Above 1 t/h the deck is too short to give the retention time you need, so a counterflow cooler with a separate grading sieve is the better buy.
What power supply does it need?
380V/50Hz three-phase. Installed power is 2.95 kW on the LQ-50 (0.75 + 2.2) and 5.15 kW on the LQ-70 (0.75 + 2.2 + 2.2). We build to your local voltage and frequency.
Does it work for wood pellets and other biomass?
Yes. It is used on feed pellets, sawdust and wood pellets, and other granular materials that need cooling and a fines cut before bagging. For very light or fluffy material tell us first — the fan and deck mesh are selected for the product.
How is dust handled?
Filter bags are standard and a cyclone is the alternative where a central dust system already exists. Either way the air is cleaned before it reaches the fan.

Get the Right LQ Model for Your Mill

Send your pellet mill model, output, pellet diameter and the product you are running. You get the model, the fan selection and the investment range within 12 hours.